FIREBEAM XTRA-AF, Firebeam Xtra Anti Fog, incl. controller+1 reflector, 7-70m
- Brand:Other
- Product Code:FIREBEAM XTRA-AF
- Availability:Please Call or Email Us to Check Availability
Your shopping cart is empty!
FIREBEAM XTRA-AF, Firebeam Xtra Anti Fog, including controller and 1 reflector, 7-70m
The standard Fire Beam Xtra package comes complete with the head unit, the low level controller, a single reflector, a user manual and a 3mm allen key. This will enable you to cover distances up to 70 metres.
The Anti-Fog version of the Firebeam Xtra, is for use in applications where condensing and fog may be an issue. The new Fire Beam Xtra now covers up to 160 metres Soon after we launched the original Fire Beam back in 2005 it became the professional choice in beam detection. Not wanting to rest on our laurels, our world renowned design team has listened to our customers and we have now created the Fire Beam Xtra. Incorporating many of your suggestions and adding our own new innovations, the new Xtra model is a permanent replacement for the original Fire Beam and the outgoing Plus model. The result has further refined this already extraordinary market leader. With new enhanced optics you can cover distances up to 160 metres, meaning for distances over 100 metres you no longer need to use two beams, saving both time and money.
Two main attributes make The Fire Beam stand out from the crowd. A motorised beam head that continually self-aligns, and a low level controller from which all major functions can be performed.
Up until now, aligning an optical beam could well have been a nightmare, often giving uncertain results that can lead to false alarms. By utilising motors within the beam head The Fire Beam can make commissioning a safer and more accurate procedure. Our unique method of using high quality stepper motors allows us to make micro adjustments of just 1/40 of 1 degree to the beam head. This is automatically controlled by software which finds and continually monitors its position in relation to the reflector. A simple commissioning procedure ensures that you achieve perfect alignment every time and that your beam will keep that alignment.
Building movement is the enemy of beam detection, as the smallest movement of a building through heat changes or settlement will move a beam off its target (imagine a couple of degrees of movement in a 100m building). The Fire Beam will continually monitor any movement and re-align itself automatically. How many times have you had to return to a site and re-align beams at high level, and at what expense?
Low level control means just that. Once you have the head in place and wired in, you can make any changes and adjustments you want from ground level. You can:
SPECIFICATIONS:
A full technical specification of the Fire Beam Xtra and associated components can be seen below, answering most of the questions you may have.
Electrical Specifications: | |
---|---|
Supply Voltage | 10.2 to 30 VDC |
Supply Current | 3.5mA (constant current) in all operational states |
Constant Current | 17mA (constant current) in fast commissioning |
Environmental Specifications: | |
Temperature | -10°C to +55°C |
Humidity | 10 to 95% RH Non-condensing |
Protection Index | IP65 when suitably mounted and terminated |
Mechanical Specifications: | |
Beam Head | H:180mm x W:155mm x D:137mm - Weight 1.1kg |
Controller | H:185mm x W:120mm x D:62mm - Weight 0.55kg |
Mid Range Kit | H:293mm x W:293mm x D:5mm - Weight 0.8kg |
Long Range Kit | H:394mm x W:394mm x D:5mm - Weight 1.8kg |
Unistrut Adaptor | H:270mm x W:250mm x D:5mm - Weight 0.6Kg (mounts the Beam Head onto Unistrut) |
Optical Specifications: | |
Optical Wavelength | 870nm |
Maximum Angular Alignment | ±5° |
Maximum Angular Misalignment | (static not auto-aligning) Beam Head ±0.75° / Reflector ±2° |
Operational Specifications: | |
Protection Range | |
Fire Beam Xtra | As standard up to 70 metres |
Mid Range Kit | 70 to 140 metres |
Long Range Kit | 140 to 160 metres |
Alarm Sensitivity Levels | |
25% (1.25dB) to 50% (3dB) in 1% (0.05dB) increments (default 35% (1.87dB)) | |
Alarm Condition: | |
Obscuration drops to below pre-defined sensitivity level. | |
Time to Alarm Condition adjustable between 2 to 30 seconds in 1 second increments (default 10 seconds) | |
Alarm Indication: | |
Controller Status - FIRE | |
Controller Red Flashing LED | |
Head Red Flashing LED | |
Alarm Relay Change Over (CO) Contact | |
Rating 2A @ 30 VDC | |
Test / Reset Features: | |
Beam test function by controller | |
Alarm latching / auto-reset selectable (default auto-reset) | |
Alarm reset in latching mode by controller reset function, removing power for >5 seconds, apply 12 to 24 VDC to reset connections in Beam Head. | |
Fault Sensitivity Level: | |
90% | |
Fault Condition: | |
Obscuration drops to below the fault sensitivity level within 1 second | |
Power Down or Supply Voltage < 9 VDC | |
Commissioning modes, Pre-Alignment and Auto-Alignment | |
Beam turned off during Beam Maintenance | |
Time to Fault Condition adjustable, 2 to 60 seconds in 1 second increments (default 10 seconds) | |
Fault Indication: | |
Controller Status - FAULT | |
Controller Yellow Flashing LED 1 Second | |
Head Yellow Flashing LED 1 Second | |
Fault Relay Change Over (CO) Contact Rating 2A @ 30 VDC | |
Normal Condition: | |
Obscuration level is above the Alarm sensitivity level | |
Controller Status - NORMAL | |
Controller Green Flashing LED | |
Programmable on/off | |
Head Green Flashing LED | |
Programmable on/off | |
Auto-Align / Beam Contamination Compensation: | |
Auto-align during normal operation if obscuration drops below 90% for the duration of the align time set (doesn't affect normal operating mode) | |
Beam Contamination Compensation 4 hour monitoring. Compensation data available at the controller |
Contact us on sales@hunters-wholesalers.co.uk for more specific product information and pricing installation and training.
This website uses cookies. For more information click here.