• Security, Fire and Alarm Systems, CCTV and Electronic Security Wholesalers and Suppliers
PT10PROG, Pagetek Programming Kit incl. PC software and USB cable

PT10PROG, Pagetek Programming Kit incl. PC software and USB cable

Please contact sales on 01628 669124 or email sales@hunters-wholesalers.co.uk for a quote on this product 


PT10PROG, Programming kit for PT series, consisting of PC software and USB cable

A range of standard program settings are available from stock, together with a bespoke service, and terminal software is available for customers who wish to undertake their own programming.

The forerunner of PageTek 2, the Scope PageTek SCPUHF (nonprogrammable), will also continue to be manufactured to support simple applications and existing customer systems

Programming Overview:

Sope PageTek 3 paging transmitters are available with either 5 or 10 programmable zone inputs which, When triggered, will automatically send the active zone message to portable or fixed pagers.This message can be repeated at predetermined intervals and a secondary message can be sent when the zone returns to its inactive state if required.

Multiple transmitters can be deployed at various locations all signalling to the same pager/pager groups.

The units are also available labelled ‘DigiLink’for telemetry operation to fixed receivers.

Regular ‘In Service’ calls can be automatically sent to the receiving devices which can indicate ‘No Service’on the pagers, or trigger a ‘fault’ zone on fixed receivers if the calls are not received. This gives the end-user confidence that the system is operating properly.

The 10 zone version also has a special ‘Burglar Alarm’ mode with configurable entry/exit delay, transit zones and entry zone. For advanced users who wish to program the unit themselves, a Programming Kit can be purchased. This consists of Windows based application software and a USB cable for PC. This allows all functions to be programmed and stored in the system ín secure non-volatile memory.

12VDC, 24VDC and mains powered versions are available, with an optional battery back-up facility for the mains version.

PC Programmable Functions:

  • Individual Zone States (normally open, normally closed or change of state)
  • Voltage Input Triggers (5-18V)
  • Input trigger time
  • Transmission Delay
  • Transmission repeat functions
  • Local output (open collector)
  • Identity code (capcode) for each zone and each state.
  • Preformed text messages, either numeric or alphanumeric.
  • Low Battery Signal
  • ’In Service’ call period
  • ’Burglar Alarm’ mode (10 zone version only)
  • Tamper zone